[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: nex2image and displaying output in NCEP N-AWIPS



Gregg,

The calibration bar units would be the only thing that the NCEP
distribution doesn't have. I can send you the 1km GINI radar files
from our LDM if that would be of use for you.

However, you may want to investigate the 1km products that NSSL
is working to produce (Ken Howard and Steve Vasiloff provided some
background to their QPESUMS product to us last year). I did modify
our GEMPAK distribution to read their NetCDF tiled files-
and hoping that they were going to produce single files rather than
tiles. The point here being that they are doing the 3-D volume level 2
radar data, and the AP/clutter removal). See the March 2005 and
May 2005 links at:
http://www.unidata.ucar.edu/community/seminars/

We are hoping to be able to distribute the QPESUMS products when they
are ready...but I haven't heard an update on the status recently.

Steve Chiswell
Unidata User Support


On Tue, 2006-02-14 at 14:31, Gregory Grosshans wrote:
> Hi Steve,
> 
> I was talking to Scott today and heard you stopped by NCEP last week. I 
> hope your visit went well.
> 
> There is renewed interest at the SPC in 1km radar mosaics. Some time ago 
> through email exchanges with you it
> appeared things would work except for the calibration bar from the GINI 
> data in the N-AWIPS core code (i.e. see email
> below).
> 
> Can you tell me if this would still be the case, that is if we were to 
> run nex2image to create a 1km mosaic from
> level-III radar products and then displaying the GINI data in NCEP 
> N-AWIPS (i.e. NMAP2)? Are you aware of
> any other limitations that may result from running the nex2image program 
> with the rest of the N-AWIPS being
> core NCEP code?
> 
> Thanks,
> Gregg
> 
> Steve Chiswell wrote:
> 
> >Gregg,
> >
> >You can get the distribution via the web. If you are running Linux,
> >then the easiest way would be to grab the binary and take the programs
> >from bin/linux. Also, you will need the $GEMTBL/unidata directory for
> >nex2image to place the appropriate platformID and calibration numbers in
> >the GINI header (Also grab the entries from $GEMTBL/sat/imgtype.tbl and
> >the color enhancements from $GEMTBL/luts mentioned in the imgtype.tbl file).
> >
> >With NCEP's plotting, you won't get a calibration bar from the GINI.
> >Our distribution has additional code to create read the calibration
> >section from the GINI.
> >
> >Steve Chiswell
> >  
> >
> >