This sounds suspiciously like a grib table problem in WRF.

On Wed, Mar 22, 2017 at 5:03 PM, Mike Leuthold <leuthold@xxxxxxxxxxxxxxxx>
wrote:

> I am getting an error with real.exe in seemingly random times.  I don't
> actually think it's a CONDUIT problem as I downloaded the awip3d directly
> and get the same problem.
>
> Domain  1: Current date being processed: 2017-03-24_06:00:00.0000, which
> is loop #  13 out of   29
>  configflags%julyr, %julday, %gmt:        2017          83 6.000000
>  metgrid input_wrf.F first_date_input = 2017-03-24_06:00:00
>  metgrid input_wrf.F first_date_nml = 2017-03-22_18:00:00
> Ignoring all time series locations beyond #   1. Increase max_ts_locs in
> namelist.input
> Timing for input          1 s.
>          flag_soil_layers read from met_em file is  1
> Using sfcprs3 to compute psfc
>  i,j =          515         114
>  target pressure and value =    11.06958      -2.457370
>  column of pressure and value =    11.49449      0.0000000E+00
>  column of pressure and value =    11.47927       128.0209
>  column of pressure and value =    11.45342       346.5604
>  column of pressure and value =    11.42688       569.4280
>  column of pressure and value =    11.39957       796.8333
>  column of pressure and value =    11.37142       1029.564
>  column of pressure and value =    11.34235       1269.082
>  column of pressure and value =    11.31232       1515.348
>  column of pressure and value =    11.28131       1769.324
>  column of pressure and value =    11.24930       2031.577
>  column of pressure and value =    11.21623       2302.089
>  column of pressure and value =    11.18206       2580.684
>  column of pressure and value =    11.14673       2867.329
>  column of pressure and value =             NaN  -2202740.
>  column of pressure and value =    8.517193       20560.38
> -------------- FATAL CALLED ---------------
> FATAL CALLED FROM FILE:  <stdin>  LINE:    5108
> troubles, could not find trapping x locations
>
> I think this is a corruption of only the 40km grids as I manually
> downloaded the 32km awip32 grids from the same time and it did work.
> Unfortunately, the 32km is not available on CONDUIT and I'd MUCH prefer
> using CONDUIT NAM grids rather than downloading from NCEP.  Anyone have any
> ideas?
> thanks.
> Mike
>
>
>
> --
> Mike Leuthold
> Manager, Regional Weather Modeling Program
> University of Arizona, Atmospheric Sciences
> 520-282-1478 (cell)
> 520-621-2863 (office)
>
> _______________________________________________
> NOTE: All exchanges posted to Unidata maintained email lists are
> recorded in the Unidata inquiry tracking system and made publicly
> available through the web.  Users who post to any of the lists we
> maintain are reminded to remove any personal information that they
> do not want to be made public.
>
>
> conduit mailing list
> conduit@xxxxxxxxxxxxxxxx
> For list information or to unsubscribe, visit:
> http://www.unidata.ucar.edu/mailing_lists/




-- 
Gerry Creager
NSSL/CIMMS
405.325.6371
++++++++++++++++++++++
“Big whorls have little whorls,
That feed on their velocity;
And little whorls have lesser whorls,
And so on to viscosity.”
Lewis Fry Richardson (1881-1953)
  • 2017 messages navigation, sorted by:
    1. Thread
    2. Subject
    3. Author
    4. Date
    5. ↑ Table Of Contents
  • Search the conduit archives: