Re: [ldm-users] missing GOES VIS since March 22

  • To: Christopher Hennon <chennon@xxxxxxxx>
  • Subject: Re: [ldm-users] missing GOES VIS since March 22
  • From: "Knight, David" <dknight@xxxxxxxxxx>
  • Date: Mon, 31 Mar 2014 14:41:16 +0000
For us it turned out to be a change in the product identifier

> It was our problem ... I found that our pqact was looking for products
> with a wavelength of 0.65 microns.  The ones coming in now are 0.63.
> I adjusted our pqact and all is well now ...

The web page that describes Unidata-Wisconsin products
reflects this change.

http://www.unidata.ucar.edu/data/datastream.html

On Mar 31, 2014, at 9:58 AM, Christopher Hennon wrote:

> Hi everyone, we seem to be getting GOES data for all channels except VIS, 
> which stopped on March 22.  Everything *seems* to be in order here - did I 
> miss a notice?
> 
> If you respond please respond to all, as I am traveling and may not be able 
> to get your message to much later.
> 
> Thanks,
> Chris
> 
> -- 
> 
> Dr. Christopher C. Hennon
> Associate Professor
> Department of Atmospheric Sciences
> UNC Asheville
> 
> 1 University Heights
> CPO #2450
> Asheville, NC 28804
> 
> 1.828.232.5159 (phone)
> 1.828.232.5046 (fax)
> 
> http://facstaff.unca.edu/chennon
> _______________________________________________
> ldm-users mailing list
> ldm-users@xxxxxxxxxxxxxxxx
> For list information or to unsubscribe,  visit: 
> http://www.unidata.ucar.edu/mailing_lists/

David Knight
Dept. of Atmospheric and Environmental Sciences  Tel: (518)-442-4204
University at Albany, ES-228                     Fax: (518)-442-4494
Albany, NY  12222                              Email: dknight@xxxxxxxxxx